Heat Pumps In CT21, Hythe
Site:- Heat Pump Installation in CT21, Hythe, Nr. Folkestone, Kent.
Dwelling Description:- 279m2 – 5 bed detached property built 2011.
System Design:- Air source heat pump (ASHP), 14kW Mitsubishi Ecodan monobloc with a Kingspan 250litre heat pump cylinder. System was fitted with Stelrad radiators and was sized to a delta t of 20⁰C. Heat loss calculations showed a power requirement of 13.3kW to the property.
Job Ref:- 54
Summary – Customer happy with the running of unit in both performance and economically.
Heat Pump Installation In Seabrook CT21
Site:- Heat Pump Installation in CT21, Seabrook, Nr. Folkestone, Kent.
Dwelling Description:- 152m2 – 3 bed detached property built 2012.
System Design:- Air source heat pump (ASHP), 12kW Vaillant geoTHERM monobloc with a Powerflow 250litre heat pump/solar cylinder. System was fitted with Stelrad radiators and was sized to a delta t of 20⁰C. Heat loss calculations showed a power requirement of 5.98kW to the property.
Job Ref:- 11041
Summary:– Contractor happy with the professionalism of the Reina Group and the quality of their aftercare.