Heat Pump Installation In Rye, Tonbridge, TN31
Site:- Beach House, Camber Sands, Rye TN31
Dwelling Description:- 221m2 – 4 bed detached Beach Property Built 2014.
Ground Source Heat Pump Installation
System Design:- Ground source heat pump (GSHP) – 8kW Danfoss DHP-L Opti Pro with a Danfoss 400litre heat pump cylinder and 120litre buffer vessel. Underfloor Heating and MVHR (mechanical ventilation heat recovery) designed & installed by Reina Group. Heat loss calculations showed a power requirement of 4.7kW for heating to the property.
Two x 102m boreholes were drilled on the beach in difficult circumstances to provide the required energy
Remote monitoring has been installed for UFH system which can be controlled by I-phone
Job Ref:- 11278 – Plant Room & UFH Manifold
Project Manager extremely pleased with quality of installation from Reina engineer on this £1m+ project